Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Prosthodont ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37626443

RESUMO

PURPOSE: To evaluate the effect of different veneering ceramics and veneering techniques on the bond strength to zirconia. MATERIALS AND METHODS: 3Y-TZP zirconia blocks were sliced into 60 slabs, polished, and sintered. Each slab received one ceramic cylinder (Ø = 3.4 mm, 5 mm-high), according to the veneering ceramic type (feldspathic-FEL or lithium disilicate-based-LD) and the veneering technique (file-splitting with resin-based luting agent-RC, file-splitting with fusion ceramic-FC, or heat-pressing-HT), which resulted in six groups: FEL-RC, FEL-FC, FEL-HT, LD-RC, LD-FC, LD-HT. After preparation, the samples were immersed in distilled water for 24 h before the shear bond strength (SBS) test. The failure modes were classified as adhesive, predominantly adhesive, or cohesive. Representative failure mode images were taken in a Scanning Electron Microscope. The SBS data were analyzed by two-way ANOVA and Tukey's test. RESULTS: Both type of veneering ceramic and technique affected the bond strength. FC led to the highest SBS values. RC and HP provided similar results when compared within each veneering ceramic. Lithium disilicate achieved lower bond strength than feldspathic ceramic when the heat-pressing technique was applied. The most frequent failure modes were predominantly adhesive and adhesive for FEL and LD, respectively. CONCLUSION: File-splitting with fusion ceramic provided the highest adhesion to zirconia when feldspathic or lithium disilicate-based ceramics were used. The heat-pressing technique for veneering with lithium disilicate significantly decreased the bond strength when compared to the feldspathic ceramic.

2.
J Adhes Dent ; 25(1): 159-166, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37551926

RESUMO

PURPOSE: To evaluate the bond strength between alternative or conventional luting agents and indirect restorative materials. MATERIALS AND METHODS: Blocks of a polymer-infiltrated ceramic network (PICN, Vita Enamic) and a feldspathic ceramic (FEL, Vita Mark II) were sliced and divided according to the luting agent: resin cement (PICN-RC, FEL-RC), flowable composite (PICN-FC, FEL-FC), or preheated composite (PICN-PH, FEL-PH). The ceramic surfaces were polished, etched with 5% hydrofluoric acid for 60 s, and then a silane layer was applied. Cylinders of the luting agents were built up on the ceramic surfaces. In half the samples, the microshear bond strength (µSBS) was tested after 24 h (baseline). The other half was tested after 5000 thermocycles (5°C-55°C) (aging). The failure modes were determined using a stereomicroscope, and the ceramic surfaces were analyzed using a scanning electron microscope. Data were statistically analyzed with two-way ANOVA. RESULTS: Thermocycling reduced the bond strength values of all experimental groups. Regarding FEL, the preheated composite obtained the highest results. Resin cement showed results similar to the flowable composite at baseline and after aging. The highest results of PICN were obtained from the preheated composite followed by resin cement and flowable composite. Significant differences among the three luting agents were observed before and after aging. The most frequent failures among the experimental groups were adhesive and cohesive in the ceramic. CONCLUSION: Bond strength results indicate that the preheated composite can be an alternative for adhesive cementation when applied on the tested feldspathic ceramic or PICN.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Propriedades de Superfície , Condicionamento Ácido do Dente/métodos , Cerâmica/química , Porcelana Dentária/química , Cimentos Dentários , Silanos/química , Teste de Materiais , Ácido Fluorídrico/química
3.
BMJ Open ; 13(3): e067390, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36997251

RESUMO

OBJECTIVE: The objective of this study was to assess the quality of clinical practice guidelines (CPGs) for the pharmacological treatment of depression along with their recommendations and factors associated with higher quality. DESIGN: We conducted a systematic review that included CPGs for the pharmacological treatment of depression in adults. DATA SOURCES: We searched for publications from 1 January 2011 to 31 December 2021, in MEDLINE, Cochrane Library, Embase, PsycINFO, BVS and 12 other databases and guideline repositories. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: We included CPGs containing recommendations for the pharmacological treatment of depression in adults at outpatient care setting, regardless of whether it met the U.S. National Academy of Medicine criteria, or not. If a CPG included recommendations for both children and adults, they were considered. No language restriction was applied. DATA EXTRACTION AND SYNTHESIS: Data extraction was also conducted independently and in duplicate, a process that was validated in a previous project. The quality of the CPGs and their recommendations were assessed by three independent reviewers using Appraisal of Guidelines for Research and Evaluation (AGREE II) and Appraisal of Guidelines for Research and Evaluation-Recommendations Excellence (AGREE-REX). A CPG was considered to be of high quality if AGREE II Domain 3 was ≥60%; while their recommendations were considered high if AGREE-REX Domain 1 was ≥60%. RESULTS: Seventeen out of 63 (27%) CPGs were classified as high quality, while 7 (11.1%) had high-quality recommendations. The factors associated with higher-scoring CPGs and recommendations in the multiple linear regression analyses were 'Handling of conflicts of interest', 'Multiprofessional team' and 'Type of institution'. 'Inclusion of patient representative in the team' was also associated with higher-quality recommendations. CONCLUSIONS: The involvement of professionals from diverse backgrounds, the handling of conflicts of interest, and the inclusion of patients' perspectives should be prioritised by developers aiming for high-quality CPGs for the treatment of depression.


Assuntos
Depressão , Medicina , Criança , Adulto , Humanos , Depressão/tratamento farmacológico , Bases de Dados Factuais , Instalações de Saúde
4.
PLoS One ; 18(2): e0281501, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36745622

RESUMO

INTRODUCTION: Depression is a serious and widespread mental health disorder. A significant proportion of patients with depression fail to remit after two antidepressant treatment trials, a condition named treatment-resistant depression (TRD). Clinical practice guidelines (CPGs) are instruments aimed to improve diagnosis and treatment. This study objective is to systematically appraise the quality and elaborate a comparison of high-quality CPGs with high-quality recommendations aimed at TRD. METHODS AND ANALYSIS: We searched several specialized databases and organizations that develop CPGs. Independent researchers assessed the quality of the CPGs and their recommendations using AGREE II and AGREE-REX instruments, respectively. We selected only high-quality CPGs that included definition and recommendations for TRD. We investigated their divergencies and convergencies as well as weak and strong points. RESULTS: Among seven high-quality CPGs with high-quality recommendations only two (Germany's Nationale Versorgungs Leitlinie-NVL and US Department of Veterans Affairs and Department of Defense-VA/DoD) included specific TRD definition and were selected. We found no convergent therapeutic strategy among these two CPGs. Electroconvulsive therapy is recommended by the NVL but not by the VA/DoD, while repetitive transcranial magnetic stimulation is recommended by the VA/DoD but not by the NVL. While the NVL recommends the use of lithium, and a non-routine use of thyroid or other hormones, psychostimulants, and dopaminergic agents the VA/DoD does not even include these drugs among augmentation strategies. Instead, the VA/DoD recommends ketamine or esketamine as augmentation strategies, while the NVL does not mention these drugs. Other differences between these CPGs include antidepressant combination, psychotherapy as a therapeutic augmentation, and evaluation of the need for hospitalization all of which are only recommended by the NVL. CONCLUSIONS: High-quality CPGs for the treatment of depression diverge regarding the definition and use of the term TRD. There is also no convergent approach to TRD from currently high-quality CPGs.


Assuntos
Depressão , Eletroconvulsoterapia , Humanos , Depressão/terapia , Depressão/tratamento farmacológico , Antidepressivos/uso terapêutico , Psicoterapia , Lítio
5.
Braz. j. oral sci ; 22: e231377, Jan.-Dec. 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1519248

RESUMO

The aim of this study was to investigate the influence of the quantity and positioning of feldspathic ceramic specimens inside the furnace on their flexural strength and translucency. The tested hypotheses were that the arrangement of specimens in the furnance would not influence 1) the translucency or 2) the biaxial strength of the porcelain. Methods: Ninety porcelain specimens were made (1.2 mm thickness and 13.5 mm diameter) and assigned into two main groups (n=15): G1 group - 15 firing cycles containing only one specimen each, always at the center of the refractory; and G5 group - 15 firing cycles containing five specimen each, where one specimen was at the center of the refractory and four specimens positioned equidistantly on the periphery. The translucency test was performed using a spectrophotometer, followed by the flexural strength test, according to ISO 6872:2015. T-student test was performed for both the mechanical and optical obtained data. Results: The flexural strength of the porcelain was not affected by the positioning (center x periphery) of the specimens inside the furnace (p =0.08), but the translucency was affected (periphery > center; p =0.009). Regarding to the number of feldspathic ceramic specimens, the biaxial flexural strength was affected (p =0.025), as well as the translucency (p <0.05). Conclusion: A higher quantity of feldspathic ceramic specimens for each firing cycle decreased its biaxial flexural strength and translucency. Also, specimens positioned at the center of the refractory became less translucent than those positioned at the periphery.


Assuntos
Humanos , Termodinâmica , Porcelana Dentária/química , Absorção Fisico-Química , Resistência à Flexão , Luz , Espectrofotometria , Temperatura , Teste de Materiais , Microscopia Eletrônica de Varredura , Fractografia
6.
Braz. j. oral sci ; 21: e224265, jan.-dez. 2022. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354719

RESUMO

Aim: This study assessed the color and translucency stability of a polymer infiltrated ceramic network (PICN) and compared it with a resin composite (RC) and a feldspathic ceramic (FEL). Methods: Disc-shaped samples of a PICN (Vita Enamic), a feldspathic ceramic (Vitablocks Mark II), and a resin composite (Brava block) were prepared from CAD/CAM blocks. PICN and RC surfaces were finished with a sequence of polishing discs and diamond paste. FEL samples received a glaze layer. The samples were subjected to 30-min immersions in red wine twice a day for 30 days. CIEL*a*b* coordinates were assessed with a spectrophotometer at baseline and after 15 and 30 days of immersion. Color alteration (ΔE00) and translucency parameter (TP00) were calculated with CIEDE2000. Average roughness was measured before the staining procedures. Color difference and translucency data were analyzed with repeated-measures ANOVA and Tukey's tests. Roughness was analyzed with the Kruskal-Wallis test. Results: Roughness was similar among the experimental groups. All materials had their color alteration significantly increased from 15 to 30 days of staining. PICN reached an intermediate ΔE00 between FEL and RC at 15 days. PICN revealed a color alteration as high as the composite after 30 days. No statistical difference was observed regarding translucency. Conclusion: PICN was not as color stable as the feldspathic ceramic at the end of the study. Its color alteration was comparable to the resin composite when exposed to red wine. However, the translucency of the tested materials was stable throughout the 30-day staining


Assuntos
Propriedades de Superfície , Teste de Materiais , Cerâmica , Desenho Assistido por Computador , Cor , Resinas Compostas
7.
Dent Mater ; 38(12): 2084-2095, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36446649

RESUMO

OBJECTIVE: To assess potential antagonist wear and survival probability of silica-infiltrated zirconia compared to glass-graded, glazed, and polished zirconia. METHODS: Table top restorations made of 3Y-TZP (3Y), 5Y-PSZ (5Y), and lithium disilicate (LD) were bonded onto epoxy resin preparations. Each zirconia was divided into five groups according to the surface treatment: polishing; glaze; polishing-glaze; glass infiltration; and silica infiltration. The LD restorations received a glaze layer. Specimens were subjected to sliding fatigue wear using a steatite antagonist (1.25 ×106 cycles, 200 N). The presence of cracks, fractures, and/or debonding was checked every one/third of the total number of cycles was completed. Roughness, microstructural, Scanning electron microscopy, wear and residual stress analyses were conducted. Kaplan-Meier, Mantel-Cox (log-rank) and ANOVA tests were performed for statistical analyses. RESULTS: The survival probability was different among the groups. Silica infiltration and polishing-glaze led to lower volume loss than glaze and glass-infiltration. Difference was observed for roughness among the zirconia and surface treatment, while lithium disilicate presented similar roughness compared to both glazed zirconia. Scanning electron microscopy revealed the removal of the surface treatment after sliding fatigue wear in all groups. Compressive stress was detected on 3Y surfaces, while tensile stress was observed on 5Y. SIGNIFICANCE: 3Y and 5Y zirconia behaved similarly regarding antagonist wear, presenting higher antagonist wear than the glass ceramic. Silica-infiltrated and polished-glazed zirconia produced lower antagonist volume loss than glazed and glass-infiltrated zirconia. Silica-infiltrated 3Y and lithium disilicate restorations were the only groups to show survival probabilities lower than 85%.


Assuntos
Vidro , Dióxido de Silício , Microscopia Eletrônica de Varredura , Resinas Epóxi
8.
Materials (Basel) ; 15(19)2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36234211

RESUMO

Stains and glaze are effective procedures for achieving an aesthetic smoothness on indirect restorations. Thus, the effect of surface-etching treatments previous to the stain layer and the glaze application on the occlusal and antagonist wear of a hybrid ceramic were evaluated against different antagonists. Disc-shaped samples were prepared from polymer-infiltrated ceramic network (PICN) blocks. The specimens were divided into eight groups, according to the surface-etching treatment and glaze application: P (polished specimens); PG (polishing plus glaze); E (hydrofluoric acid etching plus stain); EG (acid etching plus stain plus glaze); A (aluminum oxide sandblasting plus stain); AG (sandblasting plus stain plus glaze); S (self-etching primer plus stain); SG (self-etching primer plus stain plus glaze). Half of the samples were subjected to a wear simulation with a steatite antagonist, and the other half was tested using a PICN antagonist. The test parameters were: 15 N, 1.7 Hz, 6 mm of horizontal sliding, 5000 cycles. The discs and the antagonists' masses were measured before and after the wear tests. The average roughness and spacing defects were evaluated. The etching treatment affected the surface and antagonist mass loss when tested against steatite. AG showed the highest mass loss. This influence was not detected when using the PICN antagonist. The glaze application after staining ensures a smoother surface and avoids antagonist wear.

9.
PLoS One ; 17(4): e0267323, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35439270

RESUMO

INTRODUCTION: Depression is a serious and widespread mental health disorder. Although effective treatment does exist, a significant proportion of patients with depression fail to respond to antidepressant treatment trials, a condition named treatment-resistant depression. Efficient approach should be given this condition in order to revert the burden caused by depression. Clinical practice guidelines (CPGs) are evidence-based health promotion instruments to improve diagnosis and treatment. CPGs recommendations for treatment-resistant depression must be trustworthy. The objective of the proposed study is to systematically identify, appraise the quality of CPGs for the treatment of depression and elaborate a synthesis of recommendations for treatment-resistant depression of CPGs considered to be of high quality and with high quality recommendations. METHODS AND ANALYSIS: We will search the databases of organizations, such as PubMed, Embase, Cochrane Library, PsycInfo, and the Virtual Health Library, and organizations that develop CPGs. Three independent researchers will assess the quality of the CPGs and their recommendations using the AGREE II and AGREE-REX instruments, respectively. Given the identification of divergences and convergences as well as weak and strong points among high quality CPGs, our work may help developers, clinicians and eventually patients. ETHICS AND DISSEMINATION: No ethical approval is required for a systematic review, as no patient data will be used. The research results will be disseminated in conferences and submitted to a peer reviewed journal.


Assuntos
Transtorno Depressivo Resistente a Tratamento , Fragilidade , Antidepressivos/uso terapêutico , Bases de Dados Factuais , Transtorno Depressivo Resistente a Tratamento/diagnóstico , Transtorno Depressivo Resistente a Tratamento/tratamento farmacológico , Promoção da Saúde , Humanos , Revisões Sistemáticas como Assunto
10.
Braz. j. oral sci ; 20: e211670, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1254259

RESUMO

Aim: To evaluate the effect of different surface treatments and adhesive approaches on the microshear bond strength of resin cement to a polymer-infiltrated ceramic network (PICN). Methods: PICN blocks were randomly assigned into 9 groups (n=10): CTRL: no treatment; HF: 5% hydrofluoric acid etching; HF-S: HF + silane; HF-S-A: HF-S + adhesive (Adper Single Bond 2); HF-UA: HF + universal adhesive (Single Bond Universal); SB: sandblasting with 50 µm Al2O3 particles; SB-S: SB + silane; SB-S-A: SB-S + adhesive; SB-UA: SB + universal adhesive. Resin cement microcylinders (Ø = 0.96 mm; height = 1 mm) (RelyX Ultimate) were built upon the PICN surface after roughness and contact angle measurements. Next, microshear bonding tests (µSBS) were performed (0.5 mm/min) after water storage (37ºC, 90 days) and thermocycling (12,000 cycles; 5ºC-55ºC). Failure modes were observed under stereomicroscope. Bond strength data were analyzed by two-way ANOVA/Tukey's test and t-tests. Kruskal-Wallis/Dunn's tests were conducted for roughness and contact angle data (α = 0.05). Results: A rougher surface and lower contact angles were observed for Sandblasting. HF-S (18.54 ± 2.03 MPa), SB-S (19.00 ± 1.66 MPa) and SB-UA (18.07 ± 2.36 MPa) provided the highest bond strength values, followed by the other treated groups. The CTRL group resulted in lower bond strength (7.18 ± 2.34 MPa). Conclusion: Hydrofluoric acid etching followed by silane application and sandblasting followed by silane or universal adhesive are useful clinical steps to enhance bonding to PICN. Adhesive applications after HF etching have no advantages in bonding to PICN


Assuntos
Propriedades de Superfície , Cerâmica , Adesivos Dentinários , Cimentos de Resina , Abrasão Dental por Ar , Ácido Fluorídrico
11.
J. health sci. (Londrina) ; 23(3): 191-194, 20210920.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1292753

RESUMO

Despite composite resins capacity to mimic dental tissues, they can discolor over time. However, there is no information on the effect of prebrushing mouthwashes on the composite resin staining. This study aimed to evaluate the effect of prebrushing mouthwashes on the color stability of three composite resins. Twenty specimens of each resin were prepared: Filtek Z250 (3M ESPE ­S Paul, MN, USA), Charisma (Heraeus Kulzer GmbH - Hanau - Germany) e EvoluX (Dentsply- Petrópolis - Brazil). Groups were randomly divided accord to the treatment: immersion in prebrushing mouthwash (test group) or immersion in deionized water (control group). Test groups were immersed in 10 ml of prebrushing mouthwash Plax Magic (Colgate-Palmolive, São Bernardo do Campo, SP, Brazil) for 60 s three times a day during 35 days following the manufacturer's instructions. Color measurements were performed after 24 h of specimen's preparation and after 7, 14, 21, and 35 days of immersion time. Results showed that prebrushing mouthwash Plax Magic promoted a color change in all the tested materials and evaluation time. The color change was greater in composite resin Charisma, followed by Z250 and EvoluX. Therefore, prebrushing mouthwash promoted a color change in all the materials used. Composite resin Charisma demonstrated less color stability than Filtek Z250 resin and EvoluX resin, which was the most stable. (AU)


Apesar da capacidade das resinas compostas de mimetizar os tecidos dentais, esses materiais podem ter sua cor alterada com o tempo. No entanto, não há informação na literatura sobre o efeito de evidenciadores de placa na estabilidade de cor desses materiais. Este estudo teve por objetivo avaliar o efeito de um evidenciador de placa na estabilidade de cor e três resinas compostas. Para isso, 20 espécimes de cada resina foram preparados: Filtek Z250 (3M ESPE ­S Paul, MN, EUA), Charisma (Heraeus Kulzer GmbH - Hanau - Alemanha) e EvoluX (Dentsply- Petrópolis - Brasil). Os grupos foram aleatoriamente divididos de acordo com o tratamento a ser submetido: imersão no evidenciador de placa (grupo teste) ou imersão em água deionizada (grupo controle). Os grupos teste foram imersos em 10 ml do evidenciador de placa Plax Magic (Colgate Palmolive, São Bernardo do Campo, SP, Brasil) por 60 s três vezes por dia durante 35 dias, de acordo com a orientações de uso do fabricante. As leituras de cor foram feitas após 24 h da preparação dos espécimes e após 7, 14, 21 e 35 dias de imersão. Os resultados mostraram que o evidenciador de placa Plax Magic promoveu alteração de cor em todos os materiais usados e em todos os tempos de leitura. A alteração de cor foi maior na resina Charisma, seguida da Z250 e EvoluX. Portanto, o evidenciador de placa promove alteração de cor em todos os materiais testados. A resina composta Charisma demonstrou menor estabilidade de cor que as resinas Z250 e EvoluX, que, por sua vez, foi a mais estável. (AU)

12.
J. health sci. (Londrina) ; 23(2): 99-105, 20210621.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1283092

RESUMO

A wide variety of dental ceramics is launched every year. Therefore, clinicians should constantly study and update themselves to correctly indicate these materials. This cross-sectional study aimed to assess the association of dentists' academic aspects with their knowledge and the indication of dental ceramics for metal free restorations. All the dentists from private clinics who affirmed to perform prosthetic treatments on their patients in a Southern Brazilian city were personally invited to this research to avoid dropouts. Participants answered questions related to their knowledge of different dental materials, their information sources and usage frequency of ceramic materials, and related to their academic training/education. Chi-square tests were performed to evaluate the association among the outcomes (knowledge of different materials, information sources considered for material selection and their frequencies of use) and exposure variables (time since graduation and post-graduation degree). Significant associations were also submitted to Chi-square residual analysis. A response rate of 73.3% was reached. The most known and used materials were Y-TZP and porcelain veneered zirconia, respectively, whereas the least known was leucite-based ceramic. The majority of the professionals with at least 25 years since graduation claimed not to know lithium disilicate or leucite-based ceramics, and a significant number of these professionals allow the laboratory prostheses technician to choose the restorative material. In addition, most of dentists with no post-graduation said they did not have knowledge about leucite and lithium disilicate. It was evidenced that continuing education plays an important role in the dentists' attitudes regarding ceramic materials. (AU)


Uma grande variedade de cerâmicas é lançada no mercado a cada ano. Portanto, os clínicos devem se manter em constante estudo e atualização para indicar corretamente o uso desses materiais. Assim, este estudo transversal teve por objetivo avaliar a associação entre aspectos acadêmicos de dentistas com seus conhecimentos e as indicações de cerâmicas dentárias para uso em restaurações livres de metal. Para isso, todos os dentistas de clínicas privadas que afirmaram realizar tratamentos protéticos em seus pacientes em uma cidade do sul do Brasil foram pessoalmente convidados a participar desta pesquisa para evitar desistências. Os participantes responderam a questões relacionadas ao seu conhecimento sobre diferentes materiais dentários, suas fontes de informação, a frequência de uso de materiais cerâmicos, e, também, sobre sua formação acadêmica. Testes qui-quadrado foram realizados para avaliar a associação entre os desfechos (conhecimento de diferentes materiais, fontes de informação consideradas para a seleção do material e sua frequência de uso) e as variáveis de exposição (tempo desde a graduação e grau de pós-graduação). As associações significativas foram submetidas à análise de resíduos do qui-quadrado. A taxa de resposta obtida foi de 73,3%. O material mais conhecido e usado foi a Y-TZP e zircônia recoberta por porcelana, respectivamente, enquanto que o material menos conhecido foi a cerâmica a base de leucita. A maioria dos profissionais com pelo menos 25 desde a graduação afirmaram não conhecer as cerâmicas a base de dissilicato de lítio ou leucita, e um significativo número desses profissionais permitem que o técnico em prótese dentária escolha o material restaurador. Ainda, a maioria dos dentistas sem pós-graduação disseram não conhecer as cerâmicas a base de dissilicato de lítio ou leucita. Concluiu-se que a educação continuada é um fator determinante nas atitudes de dentistas em relação aos materiais cerâmicos. (AU)

13.
Dent Mater ; 37(7): 1096-1106, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33865620

RESUMO

OBJECTIVE: This study evaluated the effect of dwell time (conventional or extended) and cooling protocol (fast or slow) of self-glaze firings on the mechanical (flexural strength and crack propagation) and optical (color and translucency) properties of a porcelain-veneered zirconia system. METHODS: Bilayer disc-shaped samples were prepared (Vita VM9 + In-Ceram YZ) and divided according to the final thermal treatment: glaze firing followed by slow cooling (furnace opening at 200 °C) (G-S) or fast cooling (furnace opening at 600 °C) (G-F, manufacturer-recommended protocol), extended glaze firing (15 min of dwell time) followed by slow cooling (EG-S) or fast cooling (EG-F), or no thermal treatment (CTRL). Porcelain roughness (Ra and Rz) was measured before and after glaze firings. Color (ΔE00) and translucency (TP00) alteration were also evaluated. Flexural strength was measured with the piston-on-three-ball test and crack propagation analysis was performed after Vickers indentations. Complementary analyzes of crystalline phase and scanning electron microscopy were carried out. RESULTS: Significant effect of dwell time was observed, with extended glaze leading to higher flexural strength and shorter crack lengths. Cracks of EG groups were observed to end in clusters of crystals. Color and translucency changed below perceptibility thresholds. All treatments led to a smoother surface and EG groups reached the lowest Rz values. An extra SiO2 peak was revealed in control and EG groups. No effect of cooling protocol was found. SIGNIFICANCE: Extended glaze firing was able to improve the resistance to crack initiation and propagation of porcelain-veneered zirconia without clinically perceptible changes in optical properties.


Assuntos
Porcelana Dentária , Dióxido de Silício , Cerâmica , Análise do Estresse Dentário , Facetas Dentárias , Teste de Materiais , Propriedades de Superfície , Zircônio
14.
J Prosthodont Res ; 65(2): 202-207, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-33028795

RESUMO

PURPOSE: To evaluate the influence of quantity and positioning of veneered zirconia specimens during firing of porcelain on their fatigue performance and colorimetric differences. METHODS: Bilayer discs (Ø=15 mm) were made, following ISO 6872 guidelines, using a Y-TZP core (yttria-stabilized tetragonal zirconia polycrystal ceramic; VITA In-Ceram YZ) and a feldspathic veneering material (VITA VM9), being both layers with 0.7 mm thickness. Y-TZP discs were sintered, the veneering material was applied over it, and the bilayer specimens were fired according to two factors (n=20): 'quantity' (1 or 5 samples per firing cycle; G1 and G5 groups respectively) and 'positioning' of the specimens inside the furnace (center or periphery of the refractory tray; G5C and G5P groups, respectively). The CIEL*a*b* parameters were recorded with a spectrophotometer and the color difference (ΔE 00 ) and translucency (TP 00 ) were calculated using CIEDE2000 equations. The step-stress fatigue test was performed with the veneer facing down (region of tensile stress concentration), 10 Hz frequency, initial tension of 20 MPa for 5,000 cycles, followed by steps of 10,000 cycles using a step size of 10 MPa, up to 100 MPa; data from strength and number of cycles for failure were recorded for statistical analysis. RESULTS: Unacceptable color differences (ΔE 00 >1.8) were observed comparing G5C vs. G1 (quantity) and G5C vs. G5P (positioning), meanwhile translucency parameters were not affected. Besides, only the 'quantity' factor influenced the fatigue performance (G1>G5C). None of the tested specimens survived beyond 90N and/or 75000 cycles. CONCLUSIONS: The quantity and position of the specimens during firing influence the final color of porcelain-veneered zirconia, and firing one specimen per cycle improved the fatigue performance of the bilayer system.


Assuntos
Porcelana Dentária , Facetas Dentárias , Cerâmica , Colorimetria , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Ítrio , Zircônio
15.
J Mech Behav Biomed Mater ; 107: 103769, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32364945

RESUMO

Considering the long time spent in low frequency cyclic fatigue tests, this study aimed to evaluate the influence of loading frequency (2 Hz and 20 Hz) on the flexural fatigue strength (FFS) and on the time and number of cycles to failure of a leucite-reinforced glass-ceramic. Disc-shaped specimens were produced using leucite-reinforced glass-ceramic CAD/CAM blocks (IPS Empress CAD), according to ISO 6872/2015. Two fatigue tests were performed. The FFS (n = 17) was determined by staircase approach at a lifetime of 500,000 cycles, for 2 Hz (control - chewing frequency estimative) and 20 Hz (accelerated approach). To determine the time and the number of cycles to failure in flexural fatigue, discs (n = 20) were submitted to a cyclic loading ranging from 10 MPa to 99 MPa (60% of the monotonic strength), until a maximum of 500,000 cycles. Means, standard deviation and confidence intervals (CI) at 95% for FFS were calculated, whereas statistical differences were detected based on maximum likelihood estimations and overlapping of 95% CIs. Kaplan Meier (α = 0.05) and log rank post-hoc tests were used to analyze the time (in minutes) and the number of cycles to failure in the lifetime test. FFS did not differ significantly between 2 Hz (mean: 78 MPa; 95% CI: 69-88 MPa) and 20 Hz (mean: 84 MPa; 95% CI: 78-90 MPa). Regarding the lifetime test, there was no difference (p = 0.3) in the time to failure for 2 Hz (mean: 13 min; 95% CI: 6-20 min) and 20 Hz (mean: 69 min; 95% CI: 9-128 min). However, the group tested with 20 Hz survived a significantly (p < 0.01) higher number of cycles (mean: 82,247 cycles; 95% CI: 11,450-153,044) than the group tested with 2 Hz (mean: 1588 cycles; 95% CI: 779-2397). Therefore, in leucite-reinforced glass-ceramic fatigue strength tests, limited to a lifetime of 500,000 cycles, the use of loading frequencies up to 20 Hz did not influence the FFS estimations when compared to 2 Hz (chewing frequency estimative), and may be an alternative to accelerate data collection in this type of mechanical test. However, in lifetime tests, the use of higher loading frequencies, as 20 Hz, did not save time, since a higher number of cycles was necessary to promote the failure, when compared to 2 Hz.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície
16.
J. health sci. (Londrina) ; 21(5): https://seer.pgsskroton.com/index.php/JHealthSci/article/view/6911, 20/12/2019.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1051612

RESUMO

Little information is available about the optical behavior of glass ceramics and indirect resin composites. This study aimed to evaluate if an indirect resin composite can present similar behavior of color stability and translucency to a glass ceramic after polishing and aging in staining beverage. Specimens of a dental ceramic (IPS e.max Ceram) and an indirect resin composite (SR Adoro) were made. Half the specimens of each material were polished with disc-shaped tips. Groups were divided according to aging media: distilled water or immersion in red wine for 20 min/day during 30 days. CIE L*a*b* coordinates were measured with a spectrophotometer at baseline and after 30 days of aging. Color change was calculated by CIEDE2000 and translucency was calculated by contrast ratio (CR). Statistical analysis were performed with ANOVA and Tukey tests. Aging in red wine caused perceptible color change in both materials. Polishing only increased color change of indirect composite when aged in red wine. Ceramic groups showed greater opacity than the composite in all measurements. The indirect composite remained more translucent and results showed that it is capable of presenting color stability similar to a ceramic. However, polishing seems to increase its color change. (AU)


Pouca informação comparando o comportamento óptico de cerâmicas vítreas e resinas compostas indiretas estão disponíveis na literatura. O objetivo deste estudo foi avaliar se uma resina composta indireta pode apresentar comportamento semelhante a uma cerâmica vítrea em relação à estabilidade de cor e translucidez após polimento e envelhecimento em meio altamente pigmentante. Espécimes de uma cerâmica vítrea (IPS e.max Ceram) e uma resina composta indireta (SR Adoro) foram preparados. Metade dos espécimes de cada material foram polidas com pontas de polimento. Os grupos foram divididos conforme o meio de armazenamento: água destilada ou vinho tinto por 20 min/dia durante 30 dias. As coordenadas CIEL*a*b* foram medidas com espectrofotômetro previamente e após os 30 dias de armazenamento. A alteração de cor foi calculada pela equação CIEDE2000 e a translucidez foi calculada por razão de contraste. A análise estatística foi realizada pelos testes ANOVA e teste de Tukey. O armazenamento em vinho levou a uma alteração de cor perceptível nos dois materiais. O polimento apenas causou alteração de cor na resina composta indireta quando imersa em vinho tinto. A resina composta indireta manteve-se mais translúcida e os resultados mostraram que esse material é capaz de apresentar estabilidade de cor semelhante à cerâmica. No entanto, o polimento parece aumentar sua alteração de cor. (AU)

17.
Dent Mater ; 35(5): 807-817, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30846374

RESUMO

OBJECTIVES: A systematic review of in vitro studies was conducted to assess the effect of thermal treatments on flexural strength or critical load to failure of porcelain-veneered zirconia (PVZ). SOURCES: Literature searches were performed up to June 2018 in PubMed/MEDLINE, Scopus and Web of Science databases, with no publication year or language limits. DATA: From 393 relevant studies, 21 were selected for full-text analysis, from which 7 failed to meet the inclusion criteria. The 14 remaining papers were included in the systematic review: 8 for meta-analysis and 6 restricted to descriptive analyses. Hand searching of reference lists resulted in no additional papers. STUDY SELECTION: In vitro studies using PVZ specimens testing the influence of thermal treatments on the fracture resistance to monotonic or cyclic loading. Papers evaluating cooling rate were divided into those applying fast cooling from above the porcelain glass transition temperature (Tg), or from below it. Meta-analyses were performed separately for flexural strength and critical load to failure, using random effects at a 5% significance level. CONCLUSIONS: Delaying furnace opening at a temperature below the porcelain Tg is advised for PVZ restorations, in order to improve their fracture resistance. Additional information is required to confirm the apparent beneficial effect of self-glaze and repeated veneer firings on the mechanical properties of these restorations. Finally, in order to obtain conclusive and relevant evidence regarding thermal treatments and the fracture resistance of PVZs, future studies should concentrate on anatomically-correct crown specimens.


Assuntos
Porcelana Dentária , Facetas Dentárias , Coroas , Análise do Estresse Dentário , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Zircônio
18.
Dent Mater ; 34(9): e225-e235, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29853196

RESUMO

OBJECTIVE: To investigate the effect of intaglio surface adjustment of simplified lithium disilicate ceramic restorations adhesively cemented to a dentin-like material on its fatigue behavior. METHODS: Ceramic discs (IPS e.max CAD) were prepared and an in-Lab simulation of machining roughness was performed by grinding with SiC paper (#60). Ceramic discs were divided into 4 groups according to the internal adjustment of the cementation surface: no adjustments (CTRL); adjustment with a medium (M), fine (F), or extra fine (FF) diamond bur. Dentin-like material discs were also produced. Ceramic disc intaglio surfaces were etched (5% hydrofluoric acid; 20s) and received a silane coating. Dentin-like material discs were etched (10% hydrofluoric acid; 1min) and received a primer coating. Pairs of ceramic/dentin-like material were adhesively cemented (Multilink Automix), and fatigue failure load tests were performed using the Staircase approach (250,000 cycles; 20Hz). Roughness, topographic and fractographic analyses were performed. Statistical analyses were carried out through ANOVA tests. RESULTS: All ground groups (M=521.3 N; F=536.9 N; FF=676.2 N) presented lower fatigue failure load values than the control (1241.6 N). M diamond bur created a rougher surface than F (Ra and Rz parameters). However, FF was similar to F and M for Ra, and similar to F for Rz. SIGNIFICANCE: Bur adjustments on the intaglio surface of simplified lithium disilicate ceramic restorations greatly decreased the fatigue failure load even using an extra-fine diamond bur. Care should be taken when internal adjustments are needed.


Assuntos
Colagem Dentária/métodos , Porcelana Dentária/química , Falha de Restauração Dentária , Condicionamento Ácido do Dente , Cerâmica/química , Instrumentos Odontológicos , Materiais Dentários , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...